_reserves and residuals

Reserves and Residuals 


The reserve actuators are torques that are added about each joint to augment the actuator’s force in order to enable the simulation to run (reserves turn on when an actuator cannot produce the needed force at a given time point). To help minimize reserve torques, make an initial pass with default inputs, and then check reserves, residuals, and joint angle errors. To reduce reserves further, decrease tracking weights on coordinates with low error.


Optimal forces for reserves should be low to prevent the optimizer from "wanting" to use reserve actuators (an actuator with a large optimal force and a low excitation is "cheap" in the optimizer cost). If larger forces are needed for a successful simulation, increase the maximum control value of residuals. The residuals will then be able to generate sufficient force, but will be penalized for doing so.


Peak reserve actuator torques should typically be less than 10% of the peak joint torque.

 Peak residual forces should typically be less than 10-20 N; peak residual moments, less than 75 Nm (depending on the type of motion).

OpenSim is supported by the Mobilize Center , an NIH Biomedical Technology Resource Center (grant P41 EB027060); the Restore Center , an NIH-funded Medical Rehabilitation Research Resource Network Center (grant P2C HD101913); and the Wu Tsai Human Performance Alliance through the Joe and Clara Tsai Foundation. See the People page for a list of the many people who have contributed to the OpenSim project over the years. ©2010-2024 OpenSim. All rights reserved.